home *** CD-ROM | disk | FTP | other *** search
/ Ham Radio / Ham Radio CD-ROM (Emerald Software) (1995).ISO / mods / m-nmods / mx4000.2 < prev    next >
Text File  |  1990-09-04  |  1KB  |  23 lines

  1. MX4000.2
  2.    11.  Remove the 4 Phillips screws holding the  case  bot-
  3.         tom, then remove the case bottom.
  4.    12.  Reconnect the power supply to the scanner and set it
  5.         to 4.0 volts.
  6.    13.  Turn the scanner on.
  7.    14.  Locate a small gray  potentiometer  on  the  printed
  8.         circuit  board.   The  potentiometer looks something
  9.         like a gray plastic Phillips  screw  head.   If  the
  10.         scanner  front  panel is facing you, the pot will be
  11.         just behind the keyboard on the  left  side.  (Don't
  12.         confuse  this  pot  with  the 3 pots along the right
  13.         edge of the board.  The battery voltage  sensor  pot
  14.         is not near any other pot.)
  15.    15.  Slowly adjust the potentiometer to the threshhold at
  16.         which the low battery indicator begins to flash.
  17.  
  18.    This procedure worked with great success on  an  MX-4200,
  19.    and its battery life was increased from 2 to 7.5 hours.
  20.  
  21.    I would like to thank Rick Meyer, WB9UFL, for finding the
  22.    potentiometer  in his MX-4000, and Ron Smithberg for let-
  23.    ting me experiment with his MX-4200.